<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Medium ESP Duct VRV Archives - tunmargaircon</title>
	<atom:link href="https://www.tunmargaircon.com/product-tag/medium-esp-duct-vrv/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.tunmargaircon.com/product-tag/medium-esp-duct-vrv/</link>
	<description></description>
	<lastBuildDate>Tue, 21 Apr 2026 14:06:31 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.0.2</generator>

<image>
	<url>https://www.tunmargaircon.com/wp-content/uploads/2025/04/cropped-logo-2-32x32.png</url>
	<title>Medium ESP Duct VRV Archives - tunmargaircon</title>
	<link>https://www.tunmargaircon.com/product-tag/medium-esp-duct-vrv/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Haier VRF AC / VRV AC System 3 HP to 112 HP</title>
		<link>https://www.tunmargaircon.com/product/haier-vrf-vrv-system-3-hp-to-112-hp/</link>
					<comments>https://www.tunmargaircon.com/product/haier-vrf-vrv-system-3-hp-to-112-hp/#comments</comments>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Fri, 14 Nov 2025 10:58:38 +0000</pubDate>
				<guid isPermaLink="false">https://www.tunmargaircon.com/?post_type=product&#038;p=5116</guid>

					<description><![CDATA[<p>1. Haier MRV-5 (Standard / 2-Pipe, Heat Pump)</p>
<p>Uses full DC inverter compressors (EVI-type) for high efficiency and variable capacity.</p>
<p>Connectable indoor-unit capacity ratio: 50% – 130%.</p>
<p>Very long piping capability: max total pipe length up to 1,000 m (per certain datasheets)</p>
<p>Max lift/drop (height difference between indoor and outdoor units):</p>
<p>Outdoor unit down: ~110 m</p>
<p>Outdoor unit up: ~90 m</p>
<p>Operating ambient temperatures:</p>
<p>Cooling: up to +50 °C</p>
<p>Heating: down to –23 °C (on some models)</p>
<p>“4-way” one-piece heat exchanger: improves heat transfer by ~30% vs older designs.</p>
<p>Control / communication: supports BACnet IP protocol for integration.</p>
<p>Sound / noise: in some MRV-5 RC (heat recovery) versions, sound power level ~ 78–88 dB(A) depending on model.</p>
<p>2. Haier MRV-5 RC (Heat Recovery, 3-Pipe)</p>
<p>Enables simultaneous cooling and heating via a 3-pipe heat recovery system.</p>
<p>Power range: from 8 HP up to 88 HP (via modular combination) in some models.</p>
<p>Uses R410A refrigerant.</p>
<p>Max pipe length: 1,000 m (for flexibility in large installations) for some variants.</p>
<p>Static pressure of fans: ~110 Pa in some models.</p>
<p>Weight / dimensions (example model): 980 × 750 × 1,690 mm; net weight ~ 267 kg for a 22.4kW unit.</p>
<p>Sound levels: e.g., 57–64 dB(A) sound pressure (varies by model) per Haier spec sheet.</p>
<p>Connectable indoor units: up to 64 indoor units in some designs.</p>
<p>3. Haier MRV-S (Mini-VRF)</p>
<p>Designed for smaller commercial / large residential: supports up to 9 indoor units per outdoor unit.</p>
<p>Refrigerant line (pipe) length: up to 300 m total (per Haier).</p>
<p>Vertical lift (height difference): up to 175 m for some MRV-S units.</p>
<p>Compressor + fan: full DC-inverter compressor + DC fan motor.</p>
<p>Fan design: 21″ (serrated-edge) fan blade (in some models) for good airflow at lower noise.</p>
<p>Example capacity: MRV-S2 Heat Pump model (AU042FPERA) — cooling ~12.6 kW, heating ~14.2 kW.</p>
<p>Warranty: some MRV-S outdoor units offer 5-year parts &#38; labor (depending on region).</p>
<p>4. Haier MRV7 S (New / R32 Version)</p>
<p>Uses low-GWP R32 refrigerant (GWP = 675) to comply with newer F-Gas regulations.</p>
<p>Power / capacity options:</p>
<p>Single-fan units: 4, 5, 6 HP</p>
<p>Double-fan units: 8, 10, 12 HP</p>
<p>Pipe length: up to 300 m (single fan) / 400 m (double fan) for maximum layout flexibility.</p>
<p>Leak detection: multi-zone leak detectors built into indoor units; automatic refrigerant recovery to outdoor unit in case of leak; optional automatic shut-off valves.</p>
<p>Control precision: PID control with ±0.5°C stability to maintain setpoint.</p>
<p>Additional Technical / Performance Features (Common Across Many Haier VRF Systems)</p>
<p>Precise Temperature Control: According to Haier, some MRV-5 systems can hold temperature to within ±1°F of setpoint.</p>
<p>Oil Management: Automatic oil balancing is included in many models, which helps minimize manual work on piping.</p>
<p>Serviceability: Some outdoor units have a “swing-out” hinged electrical control box design, making service and diagnostics more accessible.</p>
<p>Corrosion Resistance: Some units use black-fin anti-corrosion coatings.</p>
<p>Example Product (for Scale)<br />
Haier MRV‑5C 16 HP Inverter VRF Outdoor Unit: This is a Haier outdoor VRF unit (cooling-only). Note: product-listings will often give you the more granular spec sheet depending on the exact HP / kW model.</p>
<p>Summary / Take-Aways<br />
Haier’s VRF line covers a wide range: from small “mini-VRF” (MRV-S) to large commercial VRF (MRV-5 / RC) to newer R32 systems (MRV7 S).</p>
<p>Their systems support very long piping and flexible layouts, making them suitable for large, complex installations.</p>
<p>Efficiency is high due to full DC inverter compressors, precision control, and advanced heat exchanger design.</p>
<p>The newer MRV7 S is more environmentally friendly (uses R32), with added safety features (leak detection).</p>
<p>The post <a href="https://www.tunmargaircon.com/product/haier-vrf-vrv-system-3-hp-to-112-hp/">Haier VRF AC / VRV AC System 3 HP to 112 HP</a> appeared first on <a href="https://www.tunmargaircon.com">tunmargaircon</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Haier VRF / VRV System 3 HP to 112 HP</strong></p>
<p>ADVANCED TECHNOLOGY<br />
Total pipe length 1000m, height drop 110m<br />
•Max. total pipe length 1000m<br />
•Max. actual pipe length 220m<br />
•Max. equivalent pipe length 260m<br />
•Max. drop between IDU&amp;ODU / 90m (outdoor unit up) / 110m<br />
(outdoor unit down)<br />
•Max. drop between IDU&amp;IDU 30m*<br />
* if the total pipe length is between 300m and 1100m or the drop between IDU<br />
and ODU more than 50m, please contact your local</p>
<p><strong>Design of control condenser with electronic expansion valve</strong><br />
The condenser is controlled by two electronic expansion valves<br />
respectively, which can reasonably use the heat exchanger area<br />
according to the demand of IDU heat exchange temperature,<br />
distribute the refrigerant flow according to the load demand, to<br />
ensure high-performance heat exchange efficiency.</p>
<p>Intelligent triple backup operation technology<br />
•For the double-compressor system, when one compressor breakdown, the other compressor can be put into backup<br />
operation immediately to ensure the user needs.<br />
•For the multi-module combination, in case of breakdown of one outdoor unit, this unit can be interrupted from the<br />
system so that the other modules can continue to operate.<br />
•Super-long backup operation time, which can reach up to 8 hours.</p>
<p><strong>Temperature approaching technology</strong><br />
The main problem of an ordinary inverter VRF system lies in<br />
that its compressor starts and stops frequently, stopping when<br />
the room temperature reaches the setting temperature and<br />
restarting when the same becomes higher than the setting<br />
temperature. Though the inverter technology has improved<br />
such a problem greatly, the energy consumption caused by<br />
system restart is still a problem that cannot be ignored.<br />
Haier MRV 5 series units adopts the temperature approaching<br />
technology, which enables the VRF system to maintain a<br />
low-frequency operating state all the time when the room<br />
temperature is close to the setting temperature but don’ t<br />
reach the setting temperature, thus avoiding the energy waste<br />
caused by frequent on/of</p>
<p>Haier SYSTEM Indoor Unit Available in-<br />
Hi-Wall Unit<br />
One way Cassette<br />
Two-Way cassette<br />
Compact Cassette<br />
Round Way Cassette<br />
Four Way Cassette<br />
Convertible<br />
Slim Duct (0/15/30Pa)<br />
Medium ESP Duct (50/150Pa)<br />
High ESP Duct(20/200Pa)<br />
High ESP Duct (100-250Pa)<br />
Builit-in Floor Standing<br />
Console<br />
High Wall<br />
Fresh Air Duct<br />
HRV (Heat ReclaimVentalation)</p>
<p>Treated Fresh Air Units Product Line Up: Outdoor Unit Available in 3HP- 112 HP</p>
<p>Cordless Remote Controller<br />
Wired Controller<br />
Group Controller<br />
Central Controller<br />
PC Monitoring System<br />
Keycard Controlled<br />
Remote Monitoring System<br />
Tenant Billing System<br />
BMS Compatibility<br />
Mobile App<br />
Remote Monitoring Service<br />
Data Concentration</p>
<p>The post <a href="https://www.tunmargaircon.com/product/haier-vrf-vrv-system-3-hp-to-112-hp/">Haier VRF AC / VRV AC System 3 HP to 112 HP</a> appeared first on <a href="https://www.tunmargaircon.com">tunmargaircon</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.tunmargaircon.com/product/haier-vrf-vrv-system-3-hp-to-112-hp/feed/</wfw:commentRss>
			<slash:comments>24</slash:comments>
		
		
			</item>
	</channel>
</rss>
