Haier VRF / VRV System 5 HP
ADVANCED TECHNOLOGY
Total pipe length 1000m, height drop 110m
Max. total pipe length 1000m
Max. actual pipe length 220m
Max. equivalent pipe length 260m
Max. drop between IDU&ODU / 90m (outdoor unit up) / 110m
(outdoor unit down)
Max. drop between IDU & IDU 30m
If the total pipe length is between 300m and 1100m or the drop between IDU and ODU more than 50m, please contact your local Authorised Service Center. Design of control condenser with electronic expansion valve. The condenser is controlled by two electronic expansion valves respectively, which can reasonably use the heat exchanger area according to the demand of IDU heat exchange temperature,distribute the refrigerant flow according to the load demand, to ensure high-performance heat exchange efficiency.
Intelligent triple backup operation technology For the double-compressor system, when one compressor breakdown, the other compressor can be put into backup operation immediately to ensure the user needs.For the multi-module combination, in case of breakdown of one outdoor unit, this unit can be interrupted from the system so that the other modules can continue to operate. Super-long backup operation time, which can reach up to 8 hours.
Temperature approaching technology-:
The main problem of an ordinary inverter VRF system lies in that its compressor starts and stops frequently, stopping when the room temperature reaches the setting temperature and restarting when the same becomes higher than the setting temperature.
Though the inverter technology has improved such a problem greatly, the energy consumption caused by
system restart is still a problem that cannot be ignored. Haier MRV 5 series units adopts the temperature approaching technology, which enables the VRF system to maintain a low-frequency operating state all the time when the room temperature is close to the setting temperature but don’ t reach the setting temperature, thus avoiding the energy waste caused by frequent on/of.
Haier SYSTEM Indoor Unit Available in-
Hi-Wall Unit
One way Cassette
Two-Way cassette
Compact Cassette
Round Way Cassette
Four Way Cassette
Convertible
Slim Duct (0/15/30Pa)
Medium ESP Duct (50/150Pa)
High ESP Duct(20/200Pa)
High ESP Duct (100-250Pa)
Builit-in Floor Standing
Console
High Wall
Fresh Air Duct
HRV (Heat ReclaimVentalation)
Treated Fresh Air Units Product Line Up: Outdoor Unit Available in 5HP- 28HP
Cordless Remote Controller
Wired Controller
Group Controller
Central Controller
PC Monitoring System
Keycard Controlled
Remote Monitoring System
Tenant Billing System
BMS Compatibility
Mobile App
5 Years Warranty On Compressor
Remote Monitoring Service
Data Concentration




Reviews